Honeywell aquastat l4006a manual

Used in like new condition honeywell aquastat type l4006a switch opens on temp increase. If the immersion well is to be replaced and if the system is filled, drain the system to a point below the boiler tapping. Factoryset stops at 180 f, 240 f, or 250 f 82 c, 116 c, or 121 c. Honeywell s high limit aquastat controllers are immersion type controllers and operate when there are temperature changes in hydronic heating systems. L4006e1067 high limit, manual reset aquastat controller, spst. Honeywell l6007, l6008, l6006, l4007, l4008 user manual. Totally enclosed micro switch snapacting switches operate on temperature rise to setpoint. Honeywell l4006, l6006 single and multifunction aquastat. Specifications honeywell l6006 user manual page 3 of 20.

Honeywell thermostat l4006b users manual 60 0915 l4006a,b,e,h. The 2 terminals will be connected until the water temp reaches the set point of the aquastat. High limit, low limit andor circulator controllers used to. L4008a1015 honeywell, manual reset aquastat controller with 100 f to 240 f.

L4006a,b,e,h aquastat controllers operation adjust the control point to correspond with the boiler manufacturer recommendations. Honeywell aquastat l8124a installation instructions manual. This version of honeywell aquastat l4006 a manual compatible with such list of devices, as. L6006a aquastat controller fits the old immersion well spud, this immersion well does not need to be replaced. Honeywell l4008a1015 120v line voltage aquastat controller. Choose from immersion controllers, universal electronic, multizone and dual aquastat controllers with a variety of temperature ranges and differentials and spst or spdt switching types. The honeywell aquastat controller is an immersiontype device for limiting or regulating the temperature of liquids in boilers, storage tanks and other applications where temperature control is required. Honeywell thermostat l4006b users manual 60 0915 l4006a,b,e,h aquastat controllers. Your local honeywell automation and control products sales office check white.

View and download honeywell l4006 installation and operation manual online. Buy honeywell l4006a1959 high or low limit aquastat, 40180f range, 2f differential, stop factoryset at 180f, no well. L6006 aquastat controller aquastat controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. Jun 14, 2020 honeywell aquastat l6006c wiring diagram wiring diagram is a simplified usual pictorial representation of an electrical circuit. View and download honeywell aquastat l4007 product data online. Jun 14, 2020 honeywell aquastat wiring diagram honeywell aquastat l4006 wiring diagram, honeywell aquastat l4006a wiring diagram, honeywell aquastat l6006a wiring diagram, every electrical arrangement is made up of various distinct pieces. When used as a controller or as a low limit, a separate high limit must be used. Gas furnaces honeywell aquastat sit 630 eurosit gas valve manual. Aquastat relay choices from grainger operate with a 24vac thermostat or a 750mv thermostat, depending on the model. Honeywell aquastat l4006a installation instructions manual. Honeywell l4006a 2007 aquastat controller, immersion type, opens on rise, 100240f. Check the ratings given in the instructions and on.

Honeywell home boiler aquastat temperature controller. Honeywell technical support information, product brochures and more. The aquastat uses an immersion system that has two switches controlling the high and low temperature limits on the heater. Item has very minor scratches and the bottom knockout is removed with a 12 romex connector installed.

Honeywell aquastat l4007 product data pdf download manualslib. This honeywell l4008e1156 manual reset aquastat is an immersion type device that is used for restraining or balancing the temperature of liquids in boilers, storage tanks and other applications where temperature regulation is necessary. Single and multifunction aquastat controllers l4006, l6006 aquastat controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. L4006ebhigh limit f to 290 f 54 c to 141 c manual reset horizontal or vertical breaks s tradeline model available. A manual reset switch is included with the l4006e aquastat controller from honeywell. Honeywell l4006a,b,e,h aquastat controllers manual manuals. Aquastat controllers are immersion type devices for limiting or regulating the temperature. Each component ought to be set and linked to different parts in particular way.

The honeywell aquastat is a controller designed for boiler water control in heating systems that are either oil or gas fired. When the temperature of the controlled medium reaches a high limit setting, the l4006e breaks the control. It has an external adjustment screw that permits easy setting and an immersion element that can be inserted horizontally or vertically. Honeywell aquastat l4006a breaks the circuit on a temperature rise to the control setting.

Honeywell aquastat relays grainger industrial supply. Manual reset honeywell aquastat l4006a installation. Product data and specificationsproduct data for l4006, l4007, l4008, l6006, l6007, l6008 aquastat controllers english installation materialsl4006, l4007 aquastat controllers canadian. Nov 22, 2020 honeywell l4006a 1017 aquastat,ra89a 1074 switching relay,thermometer lot. Aquastat controllers from resideo are immersion type devices. Honeywell aquastat, immersion well aqua stat, l4006a 1678. It shows the components of the circuit as simplified shapes, and the capacity and signal associates in the middle of the devices.

Honeywell l4006e1067 high limit aquastat, 270f range. L4007a break the circuit on a temperature rise to the control setting. Aquastat l6006, aquastat l4006, aquastat l4008, aquastat l6007, aquastat l6008. Honeywell l4006a aquastat or equivalent control install the furnished honeywell immersion well into the 34 coupling installed on the recirculation tapping ez. Honeywell aquastat l6006c wiring diagram autocardesign. Honeywell aquastat l4006a installation instructions manual download installation instructions manual of honeywell aquastat l 4006a thermostat for free or view it online on. Hi, ive had a problem with my honeywell aquastat marked as l8124al8151a in that no matter how the limits are set, the domestic water is way too hot. L6006 read user manual online or download in pdf format.

Honeywell l4006a,b,e,h aquastat controllers manual honeywell ct3200 programmable thermostat manual honeywell t7300fq7300h series 2000 commercial thermostats manual. Mount the l4006a or equivalent to this immersion well. Honeywell l4081, l6081 multiple aquastat controllers. Aquastat l4006a, aquastat l4006b, aquastat l4006e, aquastat l4006h. Honeywell thermostat l4006b users manual 60 0915 l4006a,b,e. Honeywell l4006a1678 is used for high limit or low limit control. Remove plug or old immersion well from boiler tapping. Honeywell high limit aquastat controllerl4006e1091u the. For proper selections of settings, follow boiler manufacturer recommendations. This remote bulb type controller regulates the temperature in boilers and tanks. Magnesium anode rod verify that a magnesium rod is installed fig. Installation materialsinstallation instructions for l4006 l4006a, l4006b, l4006e, l4006h, regulateurs aquastat french.

Honeywell l4006a,b,e,h aquastat controllers installation manual honeywell l4006a application these boilermounted, immersion type controllers operate in response to temperature changes in hydronic heating systems. There are separate adjustments and a calibrated dial for each switch. T t l1 l2 hot l4006a or l4007a high limit aquastat controller 1 2 2 1 ignition use these aquastat controllers with copper wire only. Generally this is used as the boiler over temp control. Honeywell 120 volt, line voltage electric aquastat controller with a 100240f operating range adjustable 530f differential and 512 capillary. Buy honeywell l4006e1067 high limit aquastat, 270f range, manual reset, stop factoryset at 250f. To adjust, insert a screwdriver in the slotted screw type head located for proper selections of settings, follow boiler beneath the window in the cover.